Hand Held Refractometer
  Digital Refractometer
  PH meter
  PH Controller
   ORP Controller
  TDS meter,EC meter
  Electrode
  Hydrometer
  Thermometer
  Tachometer
  Moisture meter
  Humidity meter,
   Dew Point meter
  Digital Anemometer
  Lux Meter
  Sound level meter
 Thickness Meter,
   Coating Thickness Meter
  Spectrophotometer
  Surveying Instruments
  Halogen Leak Detector
  Electric Balance,
   Pocket scale

Infrared thermometer
J-208

Pocketsize, full functional Big display, wide range ,high performance, low price Both contact &non-contact, high accuracy, fast response
Measuring range -30~500℃
Display range :-64~1400℃
Field of view : Ф 50/400mm(D:S=8:1)
Spectral response: 8~14μm
Resolution: 0.1℃/℉
Emissive: ε0.10~1.0(Adjustable)
Auto OFF :60sec
Response time :T90=0.5sec
Measuring accuracy: 0.2% of reading±1℃
Sighting method :Non-coaxial laser spot
Main functions :MAX,MIN,AVG,DIF mode,
        SCAN,HI/LOW alarm,
      Back-light, Probe input
Power :2AA1.5V Alkaline
Battery life: >300hrs
Operating Temp: -10~50℃
Operating Humidity: 35~85%RH non-condensing
Storage Temp: -27~70℃
Dimensions/weight :138x39x28mm/130g

 



J-332C

Back light and Laser pointer on/off option
Auto power off
Low battery indication
Measuring range :-18℃ ~ 330℃(0℉ ~626℉
Auto data hold
Accuracy : ± 2℃ or ± 2%
℃/℉ selectable ℃/℉
Distance: Spot =8:1
Max, Min, Dif., Ave measurement

J-450C

Back light and Laser pointer on/off option
Auto power off
Low battery indication
Measuring range :-18℃ ~ 450℃
Auto data hold
Accuracy : ± 2℃ or ± 2%
℃/℉ selectable ℃/℉
Distance: Spot =8:1

J-520C

Back light and Laser pointer on/off option 
Auto power off 
Low battery indication 
Measuring range : -18℃~ 500℃(0℉~932℉) 
Auto data hold 
Accuracy : ± 2 ℃ or ± 2% 
℃/℉ selectable ℃/℉ 
Distance: Spot=8:1 
Max, Min, Dif., Ave measurement

J-650C

Back light and Laser pointer on/off option 
Auto power off 
Low battery indication 
Measuring range : -18℃~ 650℃
Auto data hold 
Accuracy : ± 2 ℃ or ± 2% 
℃/℉ selectable ℃/℉ 
Distance: Spot=12:1 

J-200C
Easy to use, just aim the target with a laser point, and press the button.
Temperature reading appears within a ½ second and remains on screen for 7 seconds
Large LCD screen shows readings in Fahrenheit or Celsius
Range: -4 to 390°F (-20 to 200°C)
Distance to spot size is 5:1 ratio (measures a 1-inch area one 5inch away)
MAX/MIN temperature record.
Temperature range:0 to 400°F (–20 to 200°C)
Accuracy :(–20 to -10°C) .±4°F (±2°C)(-10 to 50 °C)±2°F(±1°C)
(50 to200°C)±4°F (±2°C)
Response time 0.5 second
Operating environment 32 to 120°F (0 to 50°C)
Power 12V Alkaline battery
Distance to Spot Size (D:S) 5:1
MT-300C
Temperature range:4 to 570°F (–20 to 300°C)
Resolution : 1°C
Accuracy: –20 to 300°C 2% ±1°C
Response time 0.5 second
Emissivity: pre-set at 0.95
Sepctral response: 6-14 um
Power: 9V Alkaline battery
Distance to Spot Size (D:S) 10:1
Operating environment 32 to 120°F (0 to 50°C)
Relative humidity: 10-80% RH
MT-500C
Temperature range:-22 to 968°F (–30 to 520°C)
Resolution : 0.2°C
Accuracy: –30 to 520°C 1% ±1°C
Response time 0.5 second
Emissivity: 0.98, 0.94, 0.88, 0.80 adjustable
Sepctral response: 6-14 um
Power: 9V Alkaline battery
Distance to Spot Size (D:S) 10:1
Operating environment 32 to 120°F (0 to 50°C)
Relative humidity: 10-80% RH
ST-652(NEW!!!)
Temperature range: –25°C to 560°C (-13 to 1040°F)
Resolution : 0.2°C
Accuracy: 25°C to 560°C ±1.5% ±°C 1°C
Response time 0.5 second
Emissivity: 0.99, 0.95, 0.89, 0.85,0.79, 0.75
Sepctral response: 8-14 um
Power: 9V Alkaline battery
Distance to Spot Size (D:S) 12:1
Operating environment 32 to 120°F (0 to 50°C)
Relative humidity: 10-80% RH
MS-620(NEW!!!)
Temperature range: –25°C to 800°C (-13 to 1472°F)
Resolution : 0.2°C
Accuracy: 25°C to 800°C ±1.5% ±°C 1°C
Response time 0.5 second
Emissivity: 0.99, 0.95, 0.89, 0.85,0.79, 0.75
Sepctral response: 8-14 um
Power: 3 X 1.5V AA battery
Distance to Spot Size (D:S) 20:1
Operating environment 32 to 120°F (0 to 50°C)
Relative humidity: 10-80% RH
JT-850C(New)

1. Laser target pointer selection; High & Low Temperature alarm setup
2. Average and Difference Function; Max and Min Function
3. Data Hold on function; Data Store/Recall function; Auto power shut off
4. Temperature range: -18℃ to 850℃, 0℉ to 1568℉
5. Accuracy : ± 2% or ± 2℃
6. Distance spot ratio: 8:1
7. Emissivity: 0.95 pre-set
8. Response time & Wavelength: 500ms & (8-14) um
9. Repeatability: ± 1% or ± 1℃
Power Supply:  DC 9V battery operated (not included)
Product Size: 175 x 100 x 49mm
Net weight: 210g
JT-1250CNew)

1. Laser target pointer selection; High & Low Temperature alarm setup
2. Average and Difference Function; Max and Min Function
3. Data Hold on function; Data Store/Recall function; Auto power shut off
4. Temperature range: -18℃ to 1250℃, 0℉ to 2288℉
5. Accuracy : ± 2% or ± 2℃
6. Distance spot ratio: 30 :1
7. Emissivity: 0.10 - 0.99
8. Response time & Wavelength: 500ms & (8-14) um
9. Repeatability: ± 1% or ± 1℃
Power Supply:  DC 9V battery operated (not included)
Product Size: 200 x 138 x 57mm
Net weight: 300g
JT-1450C(New)

1. Laser target pointer selection; High & Low Temperature alarm setup
2. Average and Difference Function; Max and Min Function
3. Data Hold on function; Data Store/Recall function; Auto power shut off
4. Temperature range: -18℃ to 1450℃, 0℉ to 2648℉
5. Accuracy : ± 2% or ± 2℃
6. Distance spot ratio: 50 :1
7. Emissivity: 0.10 – 0.99
8. Response time & Wavelength: 500ms & (8-14) um
9. Repeatability: ± 1% or ± 1℃
Power Supply:  DC 9V battery operated (not included)
Product Size: 200 x 138 x 57mm
Net weight: 300g

Henan Hi-Tech Instruments Co., Ltd     www.meterchina.cn
Address: 2-1-1, No.21 Jingba Road, Zhengzhou 450003, Henan, China
Tel: +86-371-63612305,68042519,         Fax:+86-371-63616879
email:sales@meterchina.cn,     hujianwei371@yahoo.com.cn
Copyright© www.meterchina.cn     All rights reserved.

友情链接:好看的小说 都市言情小说 武装风暴 酒神 天才医生 超级电鳗分 练级狂人在异界 冠军**** 网游之修罗传说 官居一品 三国之宅行天下 官场新贵 网游小说 修真小说 校园小说 网游之最强房东 天才医生 混沌雷修 盾击 宦海纵横 三国之宅行天下 都市藏娇 邪龙道 法神重生 连连看小游戏 成人小游戏 小游戏大全 搞笑小游戏 换装小游戏 射击小游戏 益智小游戏 儿童小游戏 拳皇小游戏 在线小游戏 成人小游戏 小游戏大全 世纪管理 好看的玄幻小说