Pocketsize, full functional Big display, wide range ,high performance,
low price Both contact &non-contact, high accuracy, fast response
Measuring range -30~500℃
Display range :-64~1400℃
Field of view : Ф 50/400mm(D:S=8:1)
Spectral response: 8~14μm
Resolution: 0.1℃/℉
Emissive: ε0.10~1.0(Adjustable)
Auto OFF :60sec
Response time :T90=0.5sec
Measuring accuracy: 0.2% of reading±1℃
Sighting method :Non-coaxial laser spot
Main functions :MAX,MIN,AVG,DIF mode,
SCAN,HI/LOW alarm,
Back-light, Probe input
Power :2AA1.5V Alkaline
Battery life: >300hrs
Operating Temp: -10~50℃
Operating Humidity: 35~85%RH non-condensing
Storage Temp: -27~70℃
Dimensions/weight :138x39x28mm/130g
J-332C
Back light and Laser pointer on/off option
Auto power off
Low battery indication
Measuring range :-18℃ ~ 330℃(0℉ ~626℉
Auto data hold
Accuracy : ± 2℃ or ± 2%
℃/℉ selectable ℃/℉
Distance: Spot =8:1
Max, Min, Dif., Ave measurement
J-450C
Back light and Laser pointer on/off option
Auto power off
Low battery indication
Measuring range :-18℃ ~ 450℃
Auto data hold
Accuracy : ± 2℃ or ± 2%
℃/℉ selectable ℃/℉
Distance: Spot =8:1
J-520C
Back light and Laser pointer on/off option
Auto power off
Low battery indication
Measuring range : -18℃~ 500℃(0℉~932℉)
Auto data hold
Accuracy : ± 2 ℃ or ± 2%
℃/℉ selectable ℃/℉
Distance: Spot=8:1
Max, Min, Dif., Ave measurement
J-650C
Back light and Laser pointer on/off option
Auto power off
Low battery indication
Measuring range : -18℃~ 650℃
Auto data hold
Accuracy : ± 2 ℃ or ± 2%
℃/℉ selectable ℃/℉
Distance: Spot=12:1
J-200C
Easy to use, just aim the target with a laser point, and press the button.
Temperature reading appears within a ½ second and remains on screen for 7 seconds
Large LCD screen shows readings in Fahrenheit or Celsius
Range: -4 to 390°F (-20 to 200°C)
Distance to spot size is 5:1 ratio (measures a 1-inch area one 5inch away)
MAX/MIN temperature record.
Temperature range:0 to 400°F (–20 to 200°C)
Accuracy :(–20 to -10°C) .±4°F (±2°C)(-10 to 50 °C)±2°F(±1°C)
(50 to200°C)±4°F (±2°C)
Response time 0.5 second
Operating environment 32 to 120°F (0 to 50°C)
Power 12V Alkaline battery
Distance to Spot Size (D:S) 5:1
MT-300C
Temperature range:4 to 570°F (–20 to 300°C)
Resolution : 1°C
Accuracy: –20 to 300°C 2% ±1°C
Response time 0.5 second
Emissivity: pre-set at 0.95
Sepctral response: 6-14 um
Power: 9V Alkaline battery
Distance to Spot Size (D:S) 10:1
Operating environment 32 to 120°F (0 to 50°C)
Relative humidity: 10-80% RH
MT-500C
Temperature range:-22 to 968°F (–30 to 520°C)
Resolution : 0.2°C
Accuracy: –30 to 520°C 1% ±1°C
Response time 0.5 second
Emissivity: 0.98, 0.94, 0.88, 0.80 adjustable
Sepctral response: 6-14 um
Power: 9V Alkaline battery
Distance to Spot Size (D:S) 10:1
Operating environment 32 to 120°F (0 to 50°C)
Relative humidity: 10-80% RH
ST-652(NEW!!!)
Temperature range: –25°C to 560°C (-13 to 1040°F)
Resolution : 0.2°C
Accuracy: 25°C to 560°C ±1.5% ±°C 1°C
Response time 0.5 second
Emissivity: 0.99, 0.95, 0.89, 0.85,0.79, 0.75
Sepctral response: 8-14 um
Power: 9V Alkaline battery
Distance to Spot Size (D:S) 12:1
Operating environment 32 to 120°F (0 to 50°C)
Relative humidity: 10-80% RH
MS-620(NEW!!!)
Temperature range: –25°C to 800°C (-13 to 1472°F)
Resolution : 0.2°C
Accuracy: 25°C to 800°C ±1.5% ±°C 1°C
Response time 0.5 second
Emissivity: 0.99, 0.95, 0.89, 0.85,0.79, 0.75
Sepctral response: 8-14 um
Power: 3 X 1.5V AA battery
Distance to Spot Size (D:S) 20:1
Operating environment 32 to 120°F (0 to 50°C)
Relative humidity: 10-80% RH
JT-850C(New)
1. Laser target pointer selection; High & Low Temperature alarm setup
2. Average and Difference Function; Max and Min Function
3. Data Hold on function; Data Store/Recall function; Auto power shut off
4. Temperature range: -18℃ to 850℃, 0℉ to 1568℉
5. Accuracy : ± 2% or ± 2℃
6. Distance spot ratio: 8:1
7. Emissivity: 0.95 pre-set
8. Response time & Wavelength: 500ms & (8-14) um
9. Repeatability: ± 1% or ± 1℃
Power Supply: DC 9V battery operated (not included)
Product Size: 175 x 100 x 49mm
Net weight: 210g
JT-1250C(New)
1. Laser target pointer selection; High & Low Temperature alarm setup
2. Average and Difference Function; Max and Min Function
3. Data Hold on function; Data Store/Recall function; Auto power shut off
4. Temperature range: -18℃ to 1250℃, 0℉ to 2288℉
5. Accuracy : ± 2% or ± 2℃
6. Distance spot ratio: 30 :1
7. Emissivity: 0.10 - 0.99
8. Response time & Wavelength: 500ms & (8-14) um
9. Repeatability: ± 1% or ± 1℃
Power Supply: DC 9V battery operated (not included)
Product Size: 200 x 138 x 57mm
Net weight: 300g
JT-1450C(New)
1. Laser target pointer selection; High & Low Temperature alarm setup
2. Average and Difference Function; Max and Min Function
3. Data Hold on function; Data Store/Recall function; Auto power shut off
4. Temperature range: -18℃ to 1450℃, 0℉ to 2648℉
5. Accuracy : ± 2% or ± 2℃
6. Distance spot ratio: 50 :1
7. Emissivity: 0.10 – 0.99
8. Response time & Wavelength: 500ms & (8-14) um
9. Repeatability: ± 1% or ± 1℃
Power Supply: DC 9V battery operated (not included)
Product Size: 200 x 138 x 57mm
Net weight: 300g