Note: Difference between the two models
is the reference cell electrolyte. 65-IP is with solution form and
can be refilled. 65-IIP is in gel form which last life time, not
need to refill.
PH Combined Electrode
with Plastic Body
Model
84-IP
84-IIP
Measuring Range
0
- 14 pH
Temperature Range
0
- 60 °C
Zero
point value
7
+/- 1 pH
Junction
Ceramic
Reference Cell
Ag/Agcl,
KCL gel
Size
dia.10 x length
120 mm
Plug
BNC + 1 m cable
BNC
Note: 84-IP can be generally used in lab. 84-IIP is the accessory
electrode for pH meter model P-IA and PX-IA. It has a special direct
BNC plug to be connected to pH meter.
PH Combined
Electrode with Plastic Body
Model
87-IP
87-IIP
87-IIIP
Measuring Range
0
- 14 pH
Temperature Range
0 - 60 °C
Zero
point value
7
+/- 1 pH
Junction
Ceramic
Reference Cell
Ag/Agcl,
KCL gel
Size
dia.12 x length
85mm
dia.12 x length
120 mm
dia.12 x length
90 mm
Plug
Special direct
plug
BNC
BNC + 1 m cable
Note: These three models are acceossories for Pocket pH meter PH serie.
87-IP is for PH-I. It has a special
direct plug for connection. It is smaller in size so that it
can be temperarily stored in the body of PH-I
87-IIP is for PH-II, can also be generally
used in lab.
87-IIIP is for PH-III, can also be
generally used in lab.
PH Combined
Electrode with Plastic Body
Model
88-IP
88-IIP
88-IA
Measuring Range
0
- 14 pH
Temperature Range
0
- 60 °C
Zero
point value
7
+/- 1 pH
Junction
Ceramic
Reference Cell
Ag/Agcl,
KCL gel
Ag/Agcl, KCL
gel (tine vesicle)
Size
dia.12 x length
160 mm
Plug
BNC
+ 1 m cable
Note: General lab and field use pH electrodes.
Difference between 88-IP is 88-IIP is only the color.
88-IA has sharp tip.
PH Combined
Electrode with Plastic Body
Model
89-I
Measuring Range
0 - 14 pH
Temperature Range
0 - 60 °C
Zero
point value
7 +/- 1 pH
Junction
Ceramic
Reference Cell
Ag/Agcl, KCL
gel
Size
dia.12 x length
170 mm
Plug
BNC
Note: With direct BNC plug for general lab and field
use
PH Combined
Electrode with Plastic Body (double layer)
Model
99-I
99-IA
Measuring Range
0
- 14 pH
Temperature Range
0
- 60 °C
Zero
point value
7
+/- 1 pH
Junction
Fiber
Reference Cell
Ag/Agcl, KCL
gel
Ag/Agcl, KCL
gel (tine vesicle)
Size
dia.12
x length 160 mm
Plug
BNC
+ 1 m cable
Note: Double layer electrodes. Suitable for continous measurement. 99-IA
is with sharp tip.
PH Combined
Electrode with Plastic Body
Model
PS-02
Measuring Range
0 - 14 pH
Temperature Range
0 - 60 °C
Zero
point value
7 +/- 1 pH
Junction
Ceramic
Reference Cell
Ag/Agcl, KCL
gel
Size
dia.12 x length
90 mm
Plug
BNC + 1 m cable
Note: Can
be used for measuring skin, sheet, wood and etc.
PH Combined
Electrode with Plastic Body (with temperature
sensor)
Model
PE-200
Measuring Range
0 - 14 pH
Temperature Range
0 - 60 °C
ATC
Zero
point value
7 +/- 1 pH
Junction
Ceramic
Reference Cell
Ag/Agcl, KCL
gel
Size
dia.12 x length
160 mm
Plug
BNC + 1 m cable
+ temp. sensor plug
Note: With temperature sensor, can be used with pH meters with ATC (Automatic
Temperature Compensation) function.
ORP Combined
Electrode with Plastic Body
Model
99Pt-A
99Pt-B
Measuring Range
+/-
1500 mV
Junction
Ceramic
Reference Cell
Ag/Agcl,
KCL gel
Sensitive Component
dia.1 x 6mm
Platinum needle
dia.6 x 2.5mm
Platinum ring
Size
dia.12
x length 160 mm
Plug
BNC
+ 1 m cable
Note: Difference between the two models is the shape of the sensitive
component. A is needle and B is ring.
Conductivity
Electrode with Glass Body
Model
DJS-1
DJS-2
Sensitive Component
5 x 5 mm platinum
plate (coated black)
5 x 7 mm platinum
plate (coated black)
Size
dia.12 x length
140 mm
dia.12 x length
150 mm
Cell Constant
1
Plug
BNC
+ 1 m cable
DO Electrode with
Plastic Body
Model
ZDO-1
Residue current
=< 0.005
uA
Response time
30 seconds
for 90%
Measuring range
0 - 20 ppm
Stability
+/- 0.2 ppm
when ambient temperature varies +/- 10 °C